Evaluation of Functional Outcome of Unstable Distal Radial Fracture Treatment: A Comparison between Internal & External Fixations

Main Article Content

S Ripon Kumar Ghosh
Nripen Kumar Kundu

Abstract

Distal radial fracture is the most common fracture of upper extremity in all age group. In recent years, fixation with distal radial locking plate and external fixator both have become widely accepted modalities for treating unstable distal radial fracture. Purpose of this study was to evaluate the functional outcome of unstable distal radial fracture (AO/OTA 2.3B2 to C3) treated by internal and external fixations. Sample size was60 with (AO/ OTA 2.3-B2 to C3) fracture as per set criteria and was treated either by distal radial locking plate or by external fixator. Quick DASH Score was used for evaluation of functional outcome of surgery. Out of 60 patients, male (75%) were more than female (25%), maximum age incidence was found in 46-55 years age group (31.7%), right side involvement was 68.3% and left side was 31.7%. Over 66% incidence was due to RTA. Type of injury was 11.7% B2, 18.3% B3, 43.3% C1, 20.0% C2 and 6.7% C3. External fixation was 58.3% and internal fixation was 41.7%. Mean ± SD duration of operation was 39.14 ± 7.017 minutes in external fixation group and 92.80 ± 21.703 minutes in internal fixation group. Functional outcome was75.9% good and 17.2% excellent in external fixation group and 52.2% good and 34.8% excellent in fixation with distal radial locking plate group according to Quick DASH Score. Postoperative complication like soft tissue infection 34.3% and delayed union 25.7% and wrist stiffness 74.3% was in external fixation group and in internal fixation group, patients had suffered from soft tissue infection 32% and wrist stiffness 56%. No patient had non-union. Mean ± SD radiological union time in external fixation group was 16.53 ± 5.386 weeks and in internal fixation group was 16.67 ± 5.264 weeks. After 12 months of surgery both external fixation and locked volar plating provide good to excellent clinical outcomes.

Article Details

How to Cite
S Ripon Kumar Ghosh, & Nripen Kumar Kundu. (2022). Evaluation of Functional Outcome of Unstable Distal Radial Fracture Treatment: A Comparison between Internal & External Fixations. International Journal of Medical Science and Clinical Research Studies, 2(01), 56–72. https://doi.org/10.47191/ijmscrs/v2-i1-10
Section
Articles

References

I. Bentohami, A., Bosma, J., Akkersdijk, G. J. M., van Dijkman, B., Goslings, J. C., Schep, N. W. L. (2014). Incidence and characteristics of distal radial fractures in an urban population in The Netherlands, Eur J Trauma Emerg Surg, 40(3): p. 357–61. doi:10.1007/s00068-014-0394-7.

II. Mellstrand-Navarro, C., Pettersson, H. J., Tornqvist, H. and Ponzer, S. (2014). The operative treatment of fractures of the distal radius is increasing: results from a nationwide Swedish study, Bone Joint J, 96-b(7): p. 963–9. doi:10.1302/ 0301-620x.96b7.33149.

III. Nagnur, R. K., Patil, A. B., Angadi, V. and Palled, G. S. (2016). Locking compression plate fixation vs external fixator for distal radius fractures, International Journal of Orthopaedics Sciences, 2(3): p. 92-96.

IV. Jupiter, J. B., Ring, D. and Weitzel, P. P. (2002). Surgical treatment of re-displaced fractures of the distal radius in patients older than 60 years, J Hand Surg Am, 27: p. 714-23.

V. Brogren, E., Petranek, M. and Atroshi, I. (2007). Incidence and characteristics of distalradius fractures in a southern Swedish region, BMC Musculoskeletal Disorders, 8: p. 48.

http://www.biomedcentral.com/1471-2474/8/48

VI. Rockwood, C. A. and Green, D. P. (2015). Rockwood and Green’s Fractures in Adults, 8th edition, Wolters Kluwer Health, Philadelphia, USA.

VII. Slutsky, D. J. (2007). External fixation of distal radius fractures, J Hand Surg Am, 32: p. 1624–1637.

VIII. Chung, K. C., Watt, A. J., Kotsis, S. V., Margaliot, Z., Haase, S. C. and Kim, H. M. (2006). Treatment of unstable distal radial fractures with the volar locking plating system, J Bone Jt Surg Am, 88: p. 2687–2694.

IX. Schnall, S. B., Kim, B. J., Abramo, A. and Kopylov, P. (2006). Fixation of distal radius fractures using a fragment-specific system, Clin Orthop, 445: p. 51–57.

X. Konstantinos, C. X., Dionysios, A. V. and Konstantinos, J. K. (2009). Classifying fractures of the distal radius: impossible or unnecessary? Review of the literature and proposal of a grouping system, Med Sci Monit, 15(3): RA67–RA74.

XI. Scot, M. L., Cory, O. N., Jonathon, D. B., Glen, A.T., Yong, K. and Fred, S. H. (2008). Biomechanical evaluation of volar loking plate for distal radius, Hand, 3(1): p. 57-60.

XII. Wilcke, M. K. T., Abbaszadegan, H. and Adolphson, P. Y. (2011). Wrist function recovers more rapidly after volar locked plating than after external fixation but the outcomes are similar after 1 year, Acta Orthopaedica, 82: p. 76-81.

XIII. Hakimi, M., Jungbluth, P., Windolf, J. and Wild, M. (2010). Functional results and complications following locking palmar plating on the distal radius: a retrospective study, J Hand Surg Eur, 35(4): p. 283–8.

XIV. Othman, A. Y. (2009). Fixation of dorsally displaced distal radius fractures with volar plate, J Trauma, 66: p. 1416-20.

XV. Marcheix, P. S., Dotzis, A., Benko, P. E., Siegler, J., Arnaud, J. P. and Charissoux, J. L. (2010). Extension fractures of the distal radius in patients older than 50: a prospective randomized study comparing fixation using mixed pins or a palmar fixed-angle plate, J Hand Surg Eur, 35: p. 645-51.

XVI. Wright, T. W., Horodyski, M. B. and Smith, D. W. (2005). Functional outcome of unstable distal radius fractures: ORIF with a volar fixed-angle tine plate versus external fixation, J Hand Surg (Am), 30: p. 289-99.

XVII. Egol, K., Walsh, M., Tejwani, N., McLaurin, T., Wynn, C. and Paksima, N. (2008). Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial, J Bone Joint Surg (Br), 90 (9): p. 1214-21.

XVIII. Rizzo, M., Katt, B. A. and Carothers, J. T. (2008). Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures, Hand (N Y), 3 (2): p. 111-7.

XIX. Wei, D. H., Raizman, N. M. and Bottino, C. J., et al. (2009). Unstable distal radial fractures treated with external fixation, a radial column plate, or a volar plate. A prospective randomized trial, J Bone Joint Surg Am, 91: p. 1568–1577.

XX. Margaliot, Z., Haase, S. C., Kotsis, S. V., Kim, H. M. and Chung, K. C. (2005) A meta-analysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures, J Hand Surg Am, 30: p. 1185–1199.

XXI. Walenkamp, M. M., Bentohami, A., Beerekamp, M. S., Peters, R. W., van der Heiden, R., Goslings, J. C. and Schep, N. W. (2013). Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis, Strategies Trauma Limb Reconstr, 8(2): p. 67–75.

XXII. Gummesson, C., Ward, M. M. and Atroshi, I. (2006). The shortened disabilities of the arm, shoulder and hand questionnaire (Quick DASH): validity and reliability based on responses within the full-length DASH, BMC Musculoskelet Disord, 7: p. 44.

XXIII. Kundu, A. K., Wale, N., Phuljhele, S., Ghritlahre, D. and Gurudatta, H. S. (2017). Intra articular distal radius fractures and volar plate fixation: a prospective study, Int J Res Orthop, 3: p. 589-94.

XXIV. Nagnur, R. K., Patil, A. B., Angadi, V. and Palled, G. S. (2016). Locking compression plate fixation vs external fixator for distal radius fractures, International Journal of Orthopaedics Sciences, 2(3): p. 92-96.

XXV. Ma, C., Deng, Q., Pu, H., Cheng, X., Kan, Y., Yang, J., Yusufu, A. and Cao, L. (2016). External fixation is more suitable for intra-articular fractures of the distal radius in elderly patients, Bone Research, 4: p. 16017. doi:10.1038/boneres.2016.

XXVI. Pradhan, R. L., Sharma, S., Pandey, B. K., Manandhar, R. R., Prasai, T., Lakhey, S. and Rijal, K. P. (2015). Comparison of volar locking plate and external fixation with K wire augmentation in unstable distal radius fractures, Nepal Med Coll J, 17(1-2): p. 67-72.

XXVII. Shukla, R., Jain, R. K., Sharma, N. K. and Kumar, R. (2014). External fixation versus volar locking plate for displaced intraarticular distal radius fractures: a prospective randomized comparative study of the functional outcomes, J Orthopaed Traumatol, 15:265–270. DOI 10.1007/s10195-014-0317-8

XXVIII. Fok, M. W. M., Klausmeyer, M. A., Fernandez, D. L., Orbay, J. L. and Bergada, A. L. (2013). Volar Plate Fixation of Intra-Articular Distal Radius Fractures: A Retrospective Study, Journal of Wrist Surgery, 2(3): p. 247-254.

XXIX. Phadnis, J., Trompeter, A., Gallagher, K., Bradshaw, L., Elliott, D. S. and Newman, K. J. (2012). Mid-term functional outcome after the internal fixation of distal radius fractures, Journal of Orthopaedic Surgery and Research, 7:4.